{"title":"Gas collector","description":null,"products":[{"product_id":"ａｓ-テドラーバッグ１つ口コック付-１０ｌ-1-枚","title":"AS Tedlar Bag with 1 mouth valve 10L 1-2711-05 1 piece","description":"Catalog number: 1-2711-05 Features: ● Uses reliable Tedlar [[RU]] film. ● Sampling bag for gas analysis made of polyvinyl fluoride resin that shows excellent resistance to various inorganic gases and organic solvents. ● Tedlar [[RU]] (polyvinyl fluoride resin) film has very little gas permeability and adsorption, making it suitable as a gas collection bag. Specifications: ● Dimensions (mm): 500 x 350 ● Thickness (mm): 0.05 ● Nozzle outer diameter (mm): φ6 ● Inner diameter (mm): φ3 ● Thickness (mm): 0.05 ● Comes with one-way cock Material\/Finish: ● Body: Tedlar [[R]] (polyvinyl fluoride resin) ● Cock, nozzle: PTFE resin","brand":"アズワン（株）","offers":[{"title":"Default Title","offer_id":49639882293547,"sku":"100-9614","price":4409.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/1009614.jpg?v=1727460763"},{"product_id":"ａｓ-テドラーバッグ１つ口コック付-１ｌ-1-枚","title":"AS Tedlar Bag 1 piece with tap 1L 1-2711-01 1 piece","description":"Catalog number: 1-2711-01 Features: ● Uses reliable Tedlar [[RU]] film. ● Sampling bag for gas analysis made of polyvinyl fluoride resin that shows excellent resistance to various inorganic gases and organic solvents. ● Tedlar [[RU]] (polyvinyl fluoride resin) film has very little gas permeability and adsorption, making it suitable as a gas collection bag. Specifications: ● Dimensions (mm): 250 x 150 ● Thickness (mm): 0.05 ● Nozzle outer diameter (mm): φ6 ● Inner diameter (mm): φ3 ● Thickness (mm): 0.05 ● Comes with one-way cock Material\/Finish: ● Body: Tedlar [[R]] (polyvinyl fluoride resin) ● Cock, nozzle: PTFE resin","brand":"アズワン（株）","offers":[{"title":"Default Title","offer_id":49639882129707,"sku":"101-1144","price":2658.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/1011144.jpg?v=1727460758"},{"product_id":"ｓｉｂａｔａ-フィルターエレメント-ｖｆｅ-０１５-５入-080870-0014-1-個","title":"SIBATA Filter Element VFE-015 5 pcs 080870-0014 1 pc","description":"Catalog number: 080870-0014 Features: ● Filter located inside the suction port of the personal mini pump PMP-001. Uses: ● For personal mini pump PMP-001 Specifications: ● Width (mm): 6 ● Depth (mm): 6 ● Height (mm): 15 ● Model: VFE-015","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49652028145963,"sku":"162-9243","price":4633.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/1629243.jpg?v=1727768817"},{"product_id":"ｓｉｂａｔａ-クイックチャージャー-ｑｃ-１０ｎ-080860-110-1-台","title":"SIBATA Quick Charger QC-10N 080860-110 1 unit","description":"Catalog number: 080860-110 Applications: ●Work environment, personal sampling, etc. Specifications: ●Model: QC-10N","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49652027621675,"sku":"136-3200","price":24684.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/1363200.jpg?v=1727768800"},{"product_id":"ｓｉｂａｔａ-ｃｏ-ｃｏ２スパン校正ガス-ｓｇ-１-080610-004-1-個","title":"SIBATA CO\/CO2 Span Calibration Gas SG-1 080610-004 1 pc","description":"Catalog number: 080610-004 Features: ● Consumables for the indoor environment measurement set IES-4000. Applications: ● For calibrating the indoor environment measurement set IES-5000. Specifications: ● Model: SG-1","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49652025458987,"sku":"168-0333","price":11557.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/1680333.jpg?v=1727768773"},{"product_id":"ｓｉｂａｔａ-ｃｏ-ｃｏ２ゼロ校正ガス-ｚｇ-１-080600-021-1-個","title":"SIBATA CO\/CO2 Zero Calibration Gas ZG-1 080600-021 1 pc","description":"Catalog number: 080600-021 Purpose: ● For calibrating indoor environment measurement set IES-5000 Specifications: ● Model: ZG-1","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49652024279339,"sku":"165-9818","price":10336.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/1659818.jpg?v=1727768765"},{"product_id":"ｇａｓｔｅｃ-気体採取器セット-カウンタ付-ｇｖ-１１０ｓ-gv-110s-1-ｓ","title":"GASTEC Gas Sampling Set (with Counter) GV-110S GV-110S 1 S","description":"Catalog number: GV-110S Features: ● Even detector tubes with many suctions are automatically counted for each suction. ● Lightweight so that even women can pull it smoothly ● Finish indicator that lets you know at a glance when the measurement is complete ● Explosion-proof construction with no exposed metal surfaces ● Automatically counts the number of suctions. ● Easy-to-read display, can be reset with simple operations. Applications: ● Used in a variety of fields and on-site Specifications: ● Dimensions (mm): 210 x 80 x 60 ● Total length (mm): 350 ● JIS K 0804 detector tube gas measuring instrument ● Automatically counts the number of suctions when the detector tube is suctioned. ● Recommended when using detector tubes with many suctions. Set contents\/accessories: ● Gas sampling device main unit, set of accessories (grease, 3 inlet rubbers), shoulder storage case ● Gas sampling device main unit, set of accessories (grease, 3 inlet rubbers), instruction manual, shoulder storage case Note: ● For accurate measurement, it is important to be able to collect a certain amount of sample without leaks. Please check with an airtight test before use. (Explanatory video: https:\/\/youtu.be\/HzfgyHp3V3E) When measuring high concentration corrosive gases, empty the device after the measurement and replace it with fresh outside air. If corrosive gas remains inside the device, it may cause deterioration or failure.","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49676468060459,"sku":"250-9532","price":28512.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2509532.jpg?v=1728246131"},{"product_id":"ｇａｓｔｅｃ-気体採取器セット-gv-100s-1-ｓ","title":"GASTEC Gas Sampling Set GV-100S 1 S","description":"Catalog number: GV-100S Features: ● Easy to operate, even with little force. ● Built-in chip breaker to cut the detector tube before measurement. ● Comes with a finish indicator that lets you know when the measurement is complete at a glance. Applications: ● Various gases can be detected and measured depending on the type of detector tube. ● For various purposes such as building management measurement, work environment measurement, indoor environment measurement, odor measurement, prevention of oxygen deficiency, office hygiene regulations, and other research and process management. Specifications: ● Dimensions (mm): 255 x 50 (cylindrical) ● Total length (mm): 350 ● JIS K0804 detector tube gas meter ● Can be used to measure hundreds of types of gas (some are excluded) ● Two-stage method of suction volume (100ml \/ 50ml per time) Set contents \/ accessories: ● Gas sampling device body, set of accessories (grease, 3 inlet rubbers), handy storage case ● Storage case ● Grease ● Inlet rubber Note: ● The expiration date is the period from the month the detector tube was manufactured. ●The expiration date of the detector tube stored in the refrigerator is the period when it is stored in the refrigerator (below 10°C). ●For accurate measurement, it is important to be able to collect a certain amount of sample without leaking. Please check with an airtight test before use. (Explanatory video: https:\/\/youtu.be\/HzfgyHp3V3E) ● Inhalation of residual corrosive gases or dust will significantly deteriorate the collector. After use, please empty the collector with clean air and clean it.","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49676467536171,"sku":"288-3279","price":24288.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2883279.jpg?v=1728246108"},{"product_id":"ｇａｓｔｅｃ-気体採取器セット-ショルダータイプ-ｇｖ-１００ｌｓ-gv-100ls-1-ｓ","title":"GASTEC Gas Sampling Set (Shoulder Type) GV-100LS GV-100LS 1 S","description":"Catalog number: GV-100LS Features: ● A chip breaker with a smooth cut surface and a safe design that prevents fragments from scattering. ● Light enough for even women to pull smoothly. ● Finish indicator that lets you know at a glance when the measurement is complete. ● Explosion-proof construction with no exposed metal surfaces. Applications: ● Used in a variety of fields and on-site Specifications: ● Dimensions (mm): 210 x 140 x 70 ● Total length (mm): 420 ● JIS K 0804 gas detector tube ● Shoulder bag included, ideal for measurements at high altitudes. Set contents\/accessories: ● Gas sampling device, set of accessories (grease, 3 inlet rubbers), shoulder case ● Gas sampling device, set of accessories (grease, 3 inlet rubbers), instruction manual, shoulder case Note: ● For accurate measurement, it is important to be able to collect a certain amount of sample without leaks. Please check with an airtight test before use. (Explanatory video: https:\/\/youtu.be\/HzfgyHp3V3E) After installation, empty the unit and replace it with fresh outside air. If corrosive gas remains inside, it may cause deterioration or failure.","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49676467372331,"sku":"250-9531","price":25872.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2509531.jpg?v=1728246101"},{"product_id":"ｇａｓｔｅｃ-ガス採集器-未知ガス定性検知管ｎｏ-２６-１０回分-26-1-箱","title":"GASTEC Gas Sampler Unknown Gas Qualitative Detector Tube No. 26 (10 uses) 26 1 box","description":"Catalogue number: 26 Features: ● Simple, quick, and on-site measurement results. ● Compared to other measurement methods, no advanced specialized knowledge or skill is required. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For use at disaster sites such as firefighting. ● For environmental measurements. Specifications: ●Target gas: unknown gas qualitative analysis (targets: ammonia, hydrogen chloride, chlorine, sulfur dioxide, nitrogen dioxide, hydrogen sulfide, LP gas, gasoline, butane) ●Width (mm): 147 ●Depth (mm): 54 ●Height (mm): 19 ●Target gas: for unknown gas qualitative analysis ●Measurement range (ppm): none as it is for qualitative analysis ●Validity period (years): 2 ●Detectable substances: ammonia, hydrogen chloride, chlorine, sulfur dioxide, nitrogen dioxide, hydrogen sulfide, LP gas, gasoline, butane ●Number of suctions: 1 time (standard) (100 ml) ●Measurement time: 30 seconds Caution: ●This product is for qualitative analysis only and is not eligible for the issuance of test results certificates, etc.","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49667826090283,"sku":"245-0355","price":2957.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2450355.jpg?v=1728033247"},{"product_id":"ｇａｓｔｅｃ-フッ化水素検知管ｎｏ-１７-１０回分-17-1-箱","title":"GASTEC Hydrogen Fluoride Detector Tube No. 17 (10 uses) 17 1 box","description":"Catalog number: 17 Features: ● Simple and quick, on-site measurement results. ● No need for advanced expertise or skill compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For environmental measurement. Specifications: ● Target gas: Hydrogen fluoride ● Width (mm): 147 ● Depth (mm): 54 ● Height (mm): 19 ● Target gas: Hydrogen fluoride ● Measurement range (ppm): 0.25 to 100 ● Validity period (years): 3 ● Scale range: 0.5 to 20 ppm ● Number of suctions: 7 times (700 ml), 4 times (reference) (400 ml), 1 time (100 ml) ● Measurement time: 6 minutes, 3 minutes, 45 seconds ● Coefficients: 1\/2, 1, 5 ● Color change: Yellow to brown ● Temperature and humidity correction: Humidity","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49667377561899,"sku":"245-0392","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2450392.jpg?v=1728026901"},{"product_id":"ｇａｓｔｅｃ-ブタン検知管ｎｏ-１０４-１０回分-104-1-箱","title":"GASTEC Butane Detector Tube No. 104 (10 uses) 104 1 box","description":"Catalogue number: 104 Features: ● Easy and quick measurement results can be obtained on-site. ● Compared to other measurement methods, no advanced expertise or skill is required. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For environmental measurement. Specifications: ● Target gas: Butane ● Width (mm): 147 ● Depth (mm): 54 ● Height (mm): 19 ● Target gas: Butane ● Measurement range (ppm): 25 to 1400 ● Validity period (years): 3 ● Measurement range: 25 to 1400 ppm ● Scale range: (25) to 1400 ppm ● Number of suctions: 1 time (standard) (100 ml) ● Measurement time: 3 minutes ● Coefficient: 1 ● Discoloration: Yellowish brown → Greenish brown ● Temperature and humidity compensation: None ● Validity period: Up to 3 years","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49667171189035,"sku":"244-0890","price":2957.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2440890.jpg?v=1728023091"},{"product_id":"ｇａｓｔｅｃ-低級炭化水素検知管ｎｏ-１０３-９回分-103-1-箱","title":"GASTEC Light Hydrocarbon Detector Tube No. 103 (9 uses) 103 1 box","description":"Catalog number: 103 Features: ● Simple, quick, and on-site measurement results. ● Compared to other measurement methods, no advanced specialized knowledge or skill is required. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For environmental measurement. Specifications: ● Target gas: Low-grade hydrocarbons ● Width (mm): 147 ● Depth (mm): 54 ● Height (mm): 19 ● Target gas: Low-grade hydrocarbons ● Measurement range (ppm): 0.05-2.4% ● Validity period (years): 2 ● Measurement range: 0.05-2.4% ● Measurement range (vol%): 0.05-2.4 ● Scale range: 0.1-1.2% ● Number of suctions: 2 times (200 ml), 1 time (standard) (100 ml), 1\/2 time (50 ml) ● Measurement time: 4 minutes, 2 minutes, 1 minute ● Coefficients: 1\/2, 1, 2 ● Discoloration: Yellowish brown to greenish brown ● Temperature and humidity correction: None ● Expiration date: Up to 2 years Caution: ● This product includes 9 detection tubes and 1 pretreatment tube, totaling 10 tubes, but two are used simultaneously for one measurement (the pretreatment tube can be used repeatedly). Therefore, the number of measurements per box is 9 times.","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49667167125803,"sku":"244-0888","price":2957.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2440888.jpg?v=1728022995"},{"product_id":"ｇａｓｔｅｃ-ガソリン検知管ｎｏ-１０１ｌ-１０回分-101l-1-箱","title":"GASTEC Gasoline Detector Tube No. 101L (10 uses) 101L 1 box","description":"Catalog number: 101L Features: ● Simple and quick, on-site measurement results. ● Compared to other measurement methods, no advanced expertise or skill is required. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For environmental measurement. Specifications: ● Target gas: Gasoline ● Width (mm): 147 ● Depth (mm): 54 ● Height (mm): 19 ● Target gas: Gasoline ● Measurement range (ppm): 30 to 2000 ● Validity period (years): 3 ● Measurement range: 30 to 2000 ppm ● Scale range: 30 to 1000 ppm ● Number of suctions: 2 times (standard) (200 ml), 1 time (100 ml) ● Measurement time: 4 minutes, 2 minutes ● Coefficient: 1, 2 ● Discoloration: Yellowish brown → Greenish brown ● Temperature and humidity compensation: None ● Expiration date: Up to 3 years","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49667153527083,"sku":"244-0886","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2440886.jpg?v=1728022731"},{"product_id":"光明理化学-気流検査器-発煙管３０１は別売-as-2-1-ｓ","title":"Komyo Rikagaku Airflow Tester (Smoke Tube 301 sold separately) AS-2 1 S","description":"Catalogue number: AS-2 Features: ● Continuously checks the airflow direction. Applications: ● Checking the function of indoor airflow and local exhaust ventilation systems. Specifications: ● Width (mm): 120 ● Height (mm): 45 ● Length (mm): 170 ● Airflow inspection device (Smoke tube 301 sold separately) Set contents\/accessories: ● Soft case, 2-piece rubber bulb Note: ● Smoke tube (301) sold separately. 300 has been discontinued.","brand":"光明理化学工業（株）","offers":[{"title":"Default Title","offer_id":49676960366891,"sku":"325-0989","price":13728.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/3250989.jpg?v=1728254673"},{"product_id":"光明理化学-気流検査器-発煙管３０１は別売-as-1-1-ｓ","title":"Komyo Rikagaku Airflow Tester (Smoke Tube 301 sold separately) AS-1 1 S","description":"Catalog number: AS-1 Features: ●Uses a smoke tube that reacts with moisture in the air to produce white smoke to check the direction and speed of airflow. Applications: ●Checking the function of indoor airflow and local exhaust ventilation systems. Specifications: ●Airflow tester (Smoke tube 301 sold separately) Set contents\/accessories: ●Main unit, soft case, rubber bulb ●Soft case, rubber bulb Notes: ●Smoke tube (301) sold separately. 300 has been discontinued.","brand":"光明理化学工業（株）","offers":[{"title":"Default Title","offer_id":49676955549995,"sku":"325-1071","price":4224.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/3251071.jpg?v=1728254560"},{"product_id":"光明理化学-真空ガス採取器-青-ap-20-1-ｓ","title":"Komyo Rikagaku Vacuum Gas Extractor (Blue) AP-20 1 S","description":"Catalogue number: AP-20 Features: ●Lightweight and easy to carry, gas concentration can be measured with a small amount of sample air. ●Can be used in explosion-proof areas as it does not require a power source. ●Antibacterial rubber is used for the grip of the main unit. Applications: ●Used for safety and hygiene management at factories and work sites in various industries. ●Nuclear power plants, chemical plants, etc. Specifications: ●Length (mm): 240 ●Total length (mm): 240 Set contents\/accessories: ●Main unit, storage case, maintenance grease, replacement rubber tube for attachment port, hand strap","brand":"光明理化学工業（株）","offers":[{"title":"Default Title","offer_id":49676940771627,"sku":"325-1063","price":21120.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/3251063.jpg?v=1728254084"},{"product_id":"ｇａｓｔｅｃ-気体検知管８１ｌ-酢酸-１０本入-81l-1-箱","title":"GASTEC Gas Detector Tube 81L Acetic Acid (10 Tubes) 81L 1 Box","description":"Catalog number: 81L Features: ● Simple and quick, on-site measurement results. ● No need for advanced expertise or skill compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For gas detection and measurement Specifications: ● Target gas: Acetic acid ● Target gas: Acetic acid ● Measurement range (ppm): 0.125 to 25 ● Validity period (years): 2 (stored in refrigerator) ● Measurement range: 0.125 to 25.0 ppm ● Scale range: (0.25) to 10.0 ppm * The minimum scale (0.25 ppm) has no numerical value and is printed with only a solid line. English: ●Number of times of suction: 2 times, 1 time (standard), 1\/2 time●Time required for measurement: (2 times) 3 minutes, (1 standard time) 1 minute 30 seconds, (1\/2 time) 45 seconds●Other gases that can be measured with this detector tube: (1) Acetic anhydride (0.6-15 ppm) (2) Acrylic acid (2-50 ppm) (3) Formic acid (5.2-130 ppm) (4) Isovaleric acid (2-50 ppm) (5) Maleic anhydride (0.8-20 ppm) (6) Methacrylic acid (1.8-45 ppm) (7) Propionic acid (3-75 ppm)●Temperature compensation available (listed in the instruction manual)●Detection limit: 0.05 ppm (2 suctions)●Store in the refrigerator●Expiration date: 2 years from date of manufacture Material\/Finish: ●Carrier (porous silica gel or silica sand) enclosed in the glass tube. Note: ●The expiration date is the period from the month the detector tube was manufactured. ●The expiration date of detection tubes stored in the refrigerator is the period kept in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49676336005419,"sku":"290-3245","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903245.jpg?v=1728242457"},{"product_id":"ｇａｓｔｅｃ-気体検知管７１-メチルメルカプタン-１０本入-71-1-箱","title":"GASTEC Gas Detector Tube 71 Methyl Mercaptan (10 pieces) 71 1 box","description":"Catalog number: 71 Features: ● Simple and quick, on-site measurement results. ● No advanced expertise or skill is required compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For gas detection and measurement Specifications: ● Target gas: Methyl mercaptan ● Target gas: Methyl mercaptan ● Measurement range (ppm): 0.25 to 140 ● Validity period (years): 3 ● Measurement range: 0.25 to 140 ppm ● Scale range: (2.5) to 70 ppm * The minimum scale (2.5 ppm) has no numerical value and is printed with only a solid line. ●Number of suctions: 10, 9, 8, 7, 6, 5, 4, 3, 2, 1 (standard), 1\/2 ●Time required for measurement: (10 times) 15 minutes, (9 times) 13 minutes 30 seconds, (8 times) 12 minutes, (7 times) 10 minutes 30 seconds, (6 times) 9 minutes, (5 times) 7 minutes 30 seconds, (4 times) 6 minutes, (3 times) 4 minutes 30 seconds, (2 times) 3 minutes, (standard 1 time) 1 minute 30 seconds, (1\/2 time) 45 seconds ●Temperature compensation available (listed in the instruction manual) ●Detection limit: 0.1 ppm (10 times suction) ●Expiration date: 2 years from date of manufacture Material\/Finish: ●Carrier (porous silica gel or silica sand) enclosed in glass tube Note: ●Expiration date is the period from the month the detector tube was manufactured. ●The expiration date of detector tubes stored in the refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49676160008491,"sku":"290-3199","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903199.jpg?v=1728238538"},{"product_id":"ｇａｓｔｅｃ-発煙管ｎｏ-５０１-501-1-箱","title":"GASTEC Smoke Tube No. 501 501 1 box","description":"Catalog number: 501 Features: ●One smoke tube can be used approximately 50 times. ●The white smoke produced by reacting with moisture in the air allows you to check the flow of gas. Applications: ●For checking the diffusion and retention of harmful gases and particles. ●For determining sampling points for work environment measurements. ●For determining and testing the installation location of local exhaust ventilation systems. ●For testing the performance of air conditioners. ●For testing asbestos dust masks. ●For testing air flow indoors and outdoors. Specifications: ●Dimensions (mm): 100 x 50 x 20 ●Length (mm): 140 ●Diameter (mm): 7 ●Total length (mm): 180 ●Refill for Smoke Tester Set No. 500 Material\/Finish: ●Glass Caution: ●White smoke irritates mucous membranes, so be careful not to inhale it.","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675869454635,"sku":"256-7025","price":2806.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2567025.jpg?v=1728231806"},{"product_id":"ｇａｓｔｅｃ-気体検知管４ｌｌ-硫化水素-１０本入-4ll-1-箱","title":"GASTEC Gas Detector Tube 4LL Hydrogen Sulfide (10 pieces) 4LL 1 box","description":"Catalog number: 4LL Features: ● Simple and quick, on-site measurement results. ● No advanced expertise or skill is required compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For gas detection and measurement ● Suitable for oxygen deficiency measurement Specifications: ● Target gas: Hydrogen sulfide ● Target gas: Hydrogen sulfide ● Measurement range (ppm): 0.25 to 120 ● Validity period (years): 3 ● Measurement range: 0.25 to 120 ppm ● Scale range: (2.5) to 60 ppm * The minimum scale (2.5 ppm) has no numerical value and is printed with only a solid line. ●Number of suctions: 10, 9, 8, 7, 6, 5, 4, 3, 2, 1 (standard), 1\/2 ●Time required for measurement: (10 times) 10 minutes, (9 times) 9 minutes, (8 times) 8 minutes, (7 times) 7 minutes, (6 times) 6 minutes, (5 times) 5 minutes, (4 times) 4 minutes, (3 times) 3 minutes, (2 times) 2 minutes, (standard 1 time) 1 minute, (1\/2 time) 30 seconds ●No temperature and humidity correction ●Detection limit: 0.1 ppm (10 times of suction) ●Expiration date: 3 years from manufacture Material\/Finish: ●Carrier (porous silica gel or silica sand) enclosed in glass tube Note: ●Expiration date is the period from the month the detector tube was manufactured. ●The expiration date of detector tubes stored in the refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675847074091,"sku":"290-3148","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903148.jpg?v=1728231397"},{"product_id":"ｇａｓｔｅｃ-気体検知管４ｌ-硫化水素-１０本入-4l-1-箱","title":"GASTEC Gas Detector Tube 4L Hydrogen Sulfide (10 Tubes) 4L 1 Box","description":"Catalog number: 4L Features: ● Simple and quick, on-site measurement results. ● Compared to other measurement methods, no advanced expertise or skill is required. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For gas detection and measurement Specifications: ● Target gas: Hydrogen sulfide ● Target gas: Hydrogen sulfide ● Measurement range (ppm): 1 to 240 ● Validity period (years): 3 ● Measurement range: 1 to 240 ppm ● Scale range: 10 to 120 ppm ●Number of suctions: 10, 9, 8, 7, 6, 5, 4, 3, 2, 1 (standard), 1\/2 ●Time required for measurement: (10 times) 7 minutes 30 seconds, (9 times) 6 minutes 45 seconds, (8 times) 6 minutes, (7 times) 5 minutes 15 seconds, (6 times) 4 minutes 30 seconds, (5 times) 3 minutes 45 seconds, (4 times) 3 minutes, (3 times) 2 minutes 15 seconds, (2 times) 1 minute 30 seconds, (standard 1 time) 45 seconds, (1\/2 time) 30 seconds ●No temperature and humidity correction ●Detection limit: 0.1 ppm (10 times suction) ●Expiration date: 3 years from manufacture Material\/Finish: ●Carrier (porous silica gel or silica sand) enclosed in glass tube Note: ●Expiration date is the period from the month the detector tube was manufactured. ●The expiration date of detector tubes stored in the refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675845632299,"sku":"290-3296","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903296.jpg?v=1728231366"},{"product_id":"ｇａｓｔｅｃ-気体検知管４ｈ-硫化水素-１０本入-4h-1-箱","title":"GASTEC Gas Detector Tube 4H Hydrogen Sulfide (10 Tubes) 4H 1 Box","description":"Catalog number: 4H Features: ●Easy and quick measurement results can be obtained on-site. ●Compared to other measurement methods, no advanced expertise or skill is required. ●Economical initial and running costs. ●No need for calibration with calibration gas (standard gas). Uses: ●For gas detection and measurement Specifications: ●Target gas: Hydrogen sulfide ●Target gas: Hydrogen sulfide ●Measurement range (ppm): 10-4000 ●Validity period (years): 3 ●Measurement range: 10-4000 ppm ●Scale range: 100-2000 ppm ●Number of suctions: 10, 9, 8, 7, 6, 5, 4, 3, 2, 1 (standard), 1\/2 ●Measurement time required: (10 times) 7 minutes 30 seconds, (9 times) 6 minutes 45 seconds, (8 times) 6 minutes, (7 times) 5 minutes 15 seconds, (6 times) 4 minutes 30 seconds, (5 times) 3 minutes 45 seconds, (4 times) 3 minutes, (3 times) 2 minutes 15 seconds, (2 times) 1 minute 30 seconds, (standard 1 time) 45 seconds, (1\/2 time) 30 seconds ●No temperature and humidity compensation ●Expiration date: 3 years from manufacture Material\/Finish: * Carrier (porous silica gel or silica sand) enclosed in glass tube. Note: * The expiration date is the period from the month the detector tube was manufactured. * The expiration date for detector tubes stored in the refrigerator is the period when stored in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675844813099,"sku":"290-3288","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903288.jpg?v=1728231345"},{"product_id":"ｇａｓｔｅｃ-気体検知管３ｍ-アンモニア-１０本入-3m-1-箱","title":"GASTEC Gas Detector Tube 3M Ammonia (10 pieces) 3M 1 box","description":"Catalog number: 3M Features: ●Easy and quick measurement results can be obtained on-site. ●Compared to other measurement methods, no advanced expertise or skill is required. ●Economical initial and running costs. ●No need for calibration with calibration gas (standard gas). English: Uses: ●For gas detection and measurement Specifications: ●Target gas: Ammonia ●Target gas: Ammonia ●Measurement range (ppm): 10-1000 ●Validity period (years): 3 ●Measurement range: 10-1000 ppm ●Scale range: 5-100 ppm ●Number of draws: 5, 4, 3, 2, 1 (reference), 1\/2 ●Measurement time required: (5 times) 4 minutes, (4 times) 3 minutes, (3 times) 2 minutes 15 seconds, (2 times) 1 minute 30 seconds, (1 reference) 45 seconds, (1\/2 time) 25 seconds ●Other gases that can be measured with this detector tube: Trimethylamine (25-250 ppm) ●Temperature compensation available (listed in the instruction manual) ●Detection limit: 2 ppm (5 draws) ●Expiration date: 3 years from date of manufacture Materials\/Finish: ●Carrier (porous silica gel or silica sand) enclosed in glass tube Note: ●The expiration date is the period from the month the detector tube is manufactured. ●The expiration date of detection tubes stored in the refrigerator is the period kept in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675634606379,"sku":"290-3172","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903172.jpg?v=1728227228"},{"product_id":"ｇａｓｔｅｃ-気体検知管３ｌａ-アンモニア-１０本入-3la-1-箱","title":"GASTEC Gas Detector Tube 3LA Ammonia (10 pieces) 3LA 1 box","description":"Catalog number: 3LA Features: ● Easy and quick, on-site measurement results. ● No need for advanced expertise or skill compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● For gas detection and measurement Specifications: ● Target gas: Ammonia ● Target gas: Ammonia ● Measurement range (ppm): 2.5 to 200 ● Validity period (years): 3 ● Measurement range: 2.5 to 200 ppm ● Scale range: 5 to 100 ppm ● Number of times of suction: 2 times, 1 time (reference), 1\/2 time ● Measurement time required: (2 times) 1 minute, (1 reference time) 30 seconds, (1\/2 time) 30 seconds ● Temperature compensation (described in the instruction manual) ● Detection limit: 0.5 ppm (2 times suction) ● Expiration date: 3 years from manufacture Material\/Finish: ● Carrier (porous silica gel or silica sand) is enclosed in the glass tube. Note: ● The expiration date is the period from the month of manufacture of the detector tube. ●The expiration date of detection tubes stored in the refrigerator is the period kept in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675634377003,"sku":"290-3156","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903156.jpg?v=1728227222"},{"product_id":"ｇａｓｔｅｃ-気体検知管３ｌ-アンモニア-１０本入-3l-1-箱","title":"GASTEC Gas Detector Tube 3L Ammonia (10 Tubes) 3L 1 Box","description":"Catalog number: 3L Features: ●Easy and quick measurement results can be obtained on-site. ●Compared to other measurement methods, no advanced expertise or skill is required. ●Economical initial and running costs. ●No need for calibration with calibration gas (standard gas). English: Uses: ●For gas detection and measurement Specifications: ●Target gas: Ammonia ●Target gas: Ammonia ●Measurement range (ppm): 0.5 to 78 ●Validity period (years): 3 ●Measurement range: 0.5 to 78 ppm Scale range: (1) to 30 ppm *The lowest scale mark (1 ppm) is a solid line only with no numerical value ●Number of draws: 2 times, 1 time (reference), 1\/2 time ●Conversion coefficient: (2 times) 1\/2 time, (1 time) 1, (1\/2 time) 2.6 ●Time required for measurement: (2 times) 1.5 minutes, (1 time) 45 seconds, (1\/2 time) 30 seconds ●Detection limit: 0.2 ppm (2 draws) ●Color change: Pink → yellow ●Temperature and humidity compensation: Temperature ●Expiration date: 3 years from date of manufacture Material\/Finish: ●Glass tube with carrier (porous silica gel, silica sand, etc.) enclosed within. Note: ●The expiration date is the period from the month the detector tube was manufactured. ●The expiration date of detection tubes stored in the refrigerator is the period kept in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675633983787,"sku":"290-3130","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903130.jpg?v=1728227218"},{"product_id":"ｇａｓｔｅｃ-気体検知管２ｌｌ-二酸化炭素-１０本入-2ll-1-箱","title":"GASTEC Gas Detector Tube 2LL Carbon Dioxide (10 pieces) 2LL 1 box","description":"Catalog number: 2LL Features: ● Easy and quick measurement results can be obtained on-site. ● No advanced expertise or skill is required compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● Gas detection and measurement ● Compliant with Building Management Act Specifications: ● Target gas: Carbon dioxide ● Target gas: Carbon dioxide ● Measurement range (ppm): 300 to 5000 ● Validity period (years): 3 ● Measurement range\/scale range: 300 to 5000 ppm ● Number of suctions: 1 time (standard) ● Conversion factor: 1 ● Measurement time required: 1 minute ● Detection limit: 30 ppm (1 time) ● Color change: Light blue to purple ● Temperature\/humidity compensation: None ● Expiration date: 3 years from manufacture Material\/Finish: ● Carrier (porous silica gel, silica sand, etc.) enclosed in a glass tube Note: ● The expiration date is the period from the month the detector tube was manufactured. ● The expiration date of detector tubes stored in the refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675374133547,"sku":"290-3121","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903121.jpg?v=1728222935"},{"product_id":"ｇａｓｔｅｃ-気体検知管２ｌｃ-二酸化炭素-１０本入-2lc-1-箱","title":"GASTEC Gas Detector Tube 2LC Carbon Dioxide (10 pieces) 2LC 1 box","description":"Catalog number: 2LC Features: ●Easy and quick measurement results can be obtained on-site. ●Compared to other measurement methods, no advanced expertise or skill is required. ●Economical initial and running costs. ●No need for calibration with calibration gas (standard gas). Uses: ●For gas detection and measurement●Complies with the Building Management Act Specifications: ●Target gas: Carbon dioxide ●Target gas: Carbon dioxide ●Measurement range (ppm): 100-4000 ●Validity period (years): 2 ●Measurement range: 100-4000 ppm Scale range: 100-2000 ppm ●Number of times of suction: 1 time (standard), 1\/2 times ●Conversion coefficient: (1 time) 1, (1\/2 time) 2 ●Time required for measurement: (1 time) 2 minutes, (1\/2 time) 1 minute ●Detection limit: 20 ppm (1 suction) ●Color change: Pale pink to orange ●Temperature and humidity correction: None ●Expiration date: 2 years from manufacture Material\/Finish: ●Carrier (porous silica gel, silica sand, etc.) enclosed in a glass tube Note: ●Expiration date is the period from the month the detector tube was manufactured. ●The expiration date of a detector tube stored in a refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49675371544875,"sku":"290-3105","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903105.jpg?v=1728222903"},{"product_id":"ｇａｓｔｅｃ-気体検知管１ｌｌ-一酸化炭素-１０本入-1ll-1-箱","title":"GASTEC Gas Detector Tube 1LL Carbon Monoxide (10 pieces) 1LL 1 box","description":"Catalog number: 1LL Features: ● Easy and quick measurement results can be obtained on-site. ● No advanced expertise or skill is required compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● Gas detection and measurement ● Compliant with Building Management Act Specifications: ● Target gas: Carbon monoxide ● Target gas: Carbon monoxide ● Measurement range (ppm): 5 to 50 ● Validity period (years): 3 ● Measurement range\/scale range: 5 to 50 ppm ● Number of times of suction: 2 times (standard) ● Conversion factor: 1 ● Measurement time required: 6 minutes ● Detection limit: 1 ppm (when suctioning twice) ● Discoloration: Yellow to dark brown ● Temperature\/humidity compensation: None ● Expiration date: 3 years from manufacture Material\/Finish: ● Carrier (porous silica gel, silica sand, etc.) enclosed in a glass tube Note: ● The expiration date is the period from the month the detector tube was manufactured. ● The expiration date of a detector tube stored in a refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49674883924267,"sku":"290-3164","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903164.jpg?v=1728214718"},{"product_id":"ｇａｓｔｅｃ-気体検知管１ｌｃ-一酸化炭素-１０本入-1lc-1-箱","title":"GASTEC Gas Detector Tube 1LC Carbon Monoxide (10 pieces) 1LC 1 box","description":"Catalog number: 1LC Features: ● Easy and quick measurement results can be obtained on-site. ● No advanced expertise or skill is required compared to other measurement methods. ● Economical initial and running costs. ● No need for calibration with calibration gas (standard gas). Applications: ● Gas detection and measurement ● Compliant with Building Management Act Specifications: ● Target gas: Carbon monoxide ● Target gas: Carbon monoxide ● Measurement range (ppm): 1 to 30 ● Validity period (years): 2 ● Measurement range\/scale range: 1 to 30 ppm ● Number of suctions: (standard) 1 time ● Conversion factor: 1 ● Measurement time required: 4 minutes ● Detection limit: 0.5 ppm ● Color change: White to pale pink ● Temperature\/humidity correction: Temperature ● Expiration date: 2 years from manufacture Material\/Finish: ● Carrier (porous silica gel, silica sand, etc.) enclosed in a glass tube Note: ● The expiration date is the period from the month the detector tube was manufactured. ● The expiration date of a detector tube stored in a refrigerator is the period in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49674883793195,"sku":"290-3113","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903113.jpg?v=1728214713"},{"product_id":"ｇａｓｔｅｃ-気体検知管１２２ｌ-トルエン-１０本入-122l-1-箱","title":"GASTEC Gas Detector Tube 122L Toluene (10 Tubes) 122L 1 Box","description":"Catalog number: 122L Features: ●Easy and quick measurement results can be obtained on-site. ●Compared to other measurement methods, no advanced expertise or skill is required. ●Economical initial and running costs. ●No need for calibration with calibration gas (standard gas). Uses: ●For gas detection and measurement●Complies with work environment measurement standards Specifications: ●Target gas: Toluene ●Target gas: Toluene ●Measurement range (ppm): 1 to 100 ●Validity period (years): 3 ●Measurement range: 1 to 100 ppm Scale range: 2 to 50 ppm ●Number of suctions: 4 times, 2 times (standard), 1 time ●Conversion coefficient: (4 times) 1\/2, (2 times) 1, (1 time) 2 ●Time required for measurement: (4 times) 6 minutes, (2 times) 3 minutes, (1 time) 1.5 minutes ●Detection limit: 0.5 ppm (when suctioning 4 times) ●Color change: White to brown ●Temperature and humidity compensation: None ●Expiration date: 3 years from date of manufacture ●Other gases that can be measured with this detector tube: (1) Cumene 2 to 100 ppm (2) Diethylbenzene 2 to 150 ppm (3) Ethylbenzene 1 to 70 ppm (4) Xylene 2 to 200 ppm Material\/Finish: * A carrier (porous silica gel, silica sand, etc.) is enclosed inside a glass tube. Note: * The expiration date is the period from the month the detector tube was manufactured. * The expiration date for detector tubes stored in a refrigerator is the period when stored in the refrigerator (below 10°C).","brand":"（株）ガステック","offers":[{"title":"Default Title","offer_id":49674664313131,"sku":"290-3261","price":2534.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/2903261.jpg?v=1728210416"},{"product_id":"ｓｉｂａｔａ-ｓｐｃミゼットインピンジャー-ｇ-１-080030-5-1-個","title":"SIBATA SPC Midget Impinger G-1 080030-5 1 piece","description":"Catalog number: 080030-5 Features: ● Manufactured with reference to the work environment measurement standards. Applications: ● For sampling specific chemical substances, gas sampling Specifications: ● Length (mm): 170 ● Diameter (mm): 28 ● Product name: SPC Midget Impinger G-1 Single ● Model: G-1 type ● Joint: SPC-24 Material\/Finish: ● Borosilicate glass-1","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698290106667,"sku":"838-2640","price":11108.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382640.jpg?v=1728619766"},{"product_id":"ｓｉｂａｔａ-ガラス繊維フィルター-ｇｂ-１００ｒ-１１０ａ-１００入-080130-031-1-個","title":"SIBATA Glass Fiber Filter GB-100R-110A 100 pcs 080130-031 1 pc","description":"Catalog number: 080130-031 Use: ● For high volume air sampler HV-500R\/-500R-4S type Specifications: ● Diameter (mm): 110 ● Product name: Φ110mm glass fiber filter, GB100R-110A 100 sheets ● Use: For HV-500F, HVC-500 ● Model: GB100R-110A type Material\/Finish: ● Glass fiber","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698293678379,"sku":"838-2666","price":46501.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382666.jpg?v=1728619816"},{"product_id":"ｓｉｂａｔａ-アスベストサンプリングホルダー-２５ｍｍ-080140-61-1-個","title":"SIBATA Asbestos Sampling Holder 25mm 080140-61 1 piece","description":"Catalog number: 080140-61 Features: ●Complies with the American NIOSH asbestos measurement method (METHOD7400). The sampling holder contains a membrane filter (pore size 0.8 μm) and a backup filter. Can be used with various samplers. Uses: ●For asbestos sampling. Specifications: ●Dimensions: Approx. Φ29 x 80 mm ●Contents: 1 box of 50 pieces ●Rubber stopper outer diameter φ(mm): O.D φ7.65 mm ●Size: Approx. φ29 x 80 mm ●Filter: Membrane φ25 mm white","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698294006059,"sku":"838-2679","price":18514.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382679.jpg?v=1728619824"},{"product_id":"ｓｉｂａｔａ-チャコールチューブ-スタンダード-１２０入-080150-053-1-箱","title":"SIBATA Charcoal Tube Standard 120 pcs 080150-053 1 box","description":"Catalog number: 080150-053 Features: ● Activated carbon with strong adsorption power for non-polar organic solvents is enclosed in a glass tube, and 20-40 mesh activated carbon is filled in two layers of 100mg and 50mg. Compliant with the Work Environment Measurement Method and NIOSH. Uses: ● For organic gas collection Specifications: ● Product name: Charcoal tube (standard type) with cutting, 120 pieces (24 pieces x 5) Material\/Finish: ● Activated carbon, glass","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698295841067,"sku":"838-2688","price":24684.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382688.jpg?v=1728619843"},{"product_id":"ｓｉｂａｔａ-チャコールチューブ-単層-１２０入-080150-0531-1-箱","title":"SIBATA Charcoal Tube Single Layer 120 pcs 080150-0531 1 box","description":"Catalog number: 080150-0531 Features: ● A product in which activated carbon is packed into a single layer in a glass tube, and 200 mg of 20 to 40 mesh activated carbon is packed inside. The method of use is the same as the standard type, and it is convenient when a second layer of activated carbon for backup is not required. Uses: ● For organic gas collection Specifications: ● Product name: Charcoal tube (single layer type) with cutting, 120 pieces (24 pieces x 5) Material\/Finish: ● Activated carbon, glass","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698296201515,"sku":"838-2689","price":24684.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382689.jpg?v=1728619849"},{"product_id":"ｓｉｂａｔａ-チャコールチューブ-ジャンボ-６０入-080150-0532-1-箱","title":"SIBATA Charcoal Tube Jumbo 60 pcs 080150-0532 1 box","description":"Catalog number: 080150-0532 Features: ●This product has a large amount of activated carbon in the glass tube, and is filled with 20 to 40 mesh activated carbon in two layers of 400 mg and 200 mg. The large outer diameter of the tube and large filling amount make it convenient for measuring high concentration organic gases and extending the measurement time. Uses: ●For collecting organic gases Specifications: ●Product name: Charcoal tube (jumbo type) 60 pieces (12 pieces x 5) Material\/Finish: ●Activated carbon, glass","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698296430891,"sku":"838-2690","price":19074.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382690.jpg?v=1728619856"},{"product_id":"ｓｉｂａｔａ-シリカゲルチューブ-スタンダード-１２０入-080150-063-1-箱","title":"SIBATA Silica Gel Tube Standard 120 Tubes 080150-063 1 Box","description":"Catalog number: 080150-063 Features: ● This product is a glass tube filled with silica gel, which has strong adsorption power for polar compounds, and is filled with two layers of 520 mg and 260 mg of 20-40 mesh silica gel. Applications: ● For organic gas collection Specifications: ● Product name: Silica gel tube (standard type) 120 pieces (24 pieces x 5) Material\/Finish: ● Silica gel, glass","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698297217323,"sku":"838-2696","price":31416.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382696.jpg?v=1728619874"},{"product_id":"ｓｉｂａｔａ-シリカゲルチューブ-スモール-６０入-080150-0631-1-箱","title":"SIBATA Silica Gel Tube Small 60 pcs 080150-0631 1 box","description":"Catalog number: 080150-0631 Features: ● A low-fill type with 20-40 mesh silica gel packed in two layers of 150mg and 75mg. Usage is the same as the standard type. Applications: ● For organic gas collection Specifications: ● Product name: Silica gel tube (small type) 60 pieces (12 pieces x 5) Material\/Finish: ● Silica gel, glass","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698297381163,"sku":"838-2697","price":16830.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382697.jpg?v=1728619880"},{"product_id":"ｓｉｂａｔａ-チャコールシリカゲルチューブ-スタンダード-１２入-080150-081-1-個","title":"SIBATA Charcoal Silica Gel Tube Standard 12 Tubes 080150-081 1 pc","description":"Catalog number: 080150-081 Features: ● A collection tube filled with both activated carbon and silica gel to simultaneously collect non-polar and polar compounds. Applications: ● For collecting organic gases Specifications: ● Product name: Charcoal silica gel tube (standard type) 12 pieces Material\/Finish: ● Activated carbon, silica gel, glass","brand":"柴田科学（株）","offers":[{"title":"Default Title","offer_id":49698297676075,"sku":"838-2700","price":5386.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8382700.jpg?v=1728619888"},{"product_id":"３ｍ-有機ガスモニター-３５００-3500-plus-1-個","title":"3M Organic Gas Monitor 3500+ 3500 PLUS 1 piece","description":"Catalog number: 3500 PLUS Features: ● Capable of sampling over 600 types of organic gases and vapors, including toluene, xylene, and acetone. ● Capable of performing air sampling required for measuring personal exposure concentrations. ● A gas monitor (passive sampler) that can be used simply by fastening it to the collar while working. Applications: ● For air sampling required for measuring personal exposure concentrations. Specifications: ● Target gas: All organic gases ● Width (mm): 35 ● Depth (mm): 15 ● Height (mm): 85 ● Measurement range: Varies depending on the type of gas ● Organic gas monitor (passive sampler)","brand":"スリーエム　ジャパン（株）安全衛生製品事業部","offers":[{"title":"Default Title","offer_id":49711320269099,"sku":"423-2262","price":4625.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/4232262.jpg?v=1728837170"},{"product_id":"３ｍ-有機ガスモニター低濃度用-３５０１-3501-plus-1-個","title":"3M Organic Gas Monitor for Low Concentrations 3501+ 3501 PLUS 1 pc","description":"Catalog number: 3501 PLUS Features: ●Can sample over 600 types of organic gases and vapors, including toluene, xylene, and acetone. ●3501+ can be used in low concentration environments. Applications: ●For air sampling required for personal exposure concentration measurement. Specifications: ●Target gas: All organic gases ●Width (mm): 25 ●Depth (mm): 18 ●Height (mm): 140 ●Measurement range: Varies depending on gas type ●Organic gas monitor (passive sampler) for low concentrations","brand":"スリーエム　ジャパン（株）安全衛生製品事業部","offers":[{"title":"Default Title","offer_id":49711321743659,"sku":"423-2263","price":6576.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/4232263.jpg?v=1728837226"},{"product_id":"３ｍ-ホルムアルデヒドモニター-３７２１-3721-plus-1-個","title":"3M Formaldehyde Monitor 3721+ 3721 PLUS 1 unit","description":"Catalog number: 3721 PLUS Features: ●Can perform formaldehyde sampling. ●Can perform air sampling required for measuring personal exposure concentrations. ●Gas monitor (passive sampler) that can be used simply by fastening it to the collar while working. Applications: ●For air sampling required for measuring personal exposure concentrations. Specifications: ●Target gases: Formaldehyde, other aldehydes, ketones ●Width (mm): 35 ●Depth (mm): 15 ●Height (mm): 85 ●Measurement range: Formaldehyde: 12.5 ppm\/8 hours ●Formaldehyde monitor","brand":"スリーエム　ジャパン（株）安全衛生製品事業部","offers":[{"title":"Default Title","offer_id":49711606825259,"sku":"423-2264","price":6576.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/4232264.jpg?v=1728845380"},{"product_id":"ｈｏｄａｋａ-スモークテスタ用-スペアフィルターペーパー-ht-1651-1-pk","title":"HODAKA Smoke Tester Spare Filter Paper HT-1651 1 PK","description":"Catalog number: HT-1651 Features: Spare filter paper for smoke testers. Specifications: 10 sheets per pack","brand":"ホダカ（株）","offers":[{"title":"Default Title","offer_id":49722667860267,"sku":"824-7958","price":1056.0,"currency_code":"JPY","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/4980\/4331\/files\/8247958.jpg?v=1729040066"}],"url":"https:\/\/kaigoro.com\/en\/collections\/%e3%82%ac%e3%82%b9%e6%8e%a1%e9%9b%86%e5%99%a8.oembed?page=3","provider":"カイゴロウ","version":"1.0","type":"link"}