Low temperature constant temperature water tank (low GWP refrigerant) LTB-250β 1 piece
Low temperature constant temperature water tank (low GWP refrigerant) LTB-250β 1 piece
Regular price
¥382,800
Regular price
Sale price
¥382,800
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
The cooling capacity has been improved by adopting a high-performance refrigerator.
The circulating water cooler uses a square coil made of SUS304, so it is compatible with pure water. (*If using pure water, please use a liquid with an electrical conductivity of 10μs/cm or more (low purity).)
Uses earth-friendly low GWP refrigerant R448A (GWP: 1386)
The GWP value is approximately 65% lower than that of the LTB-α series (GWP: 3920).
The external circulation nozzle is installed on the front of the controller and can be freely rotated 180°.
The temperature setting display uses a two-stage PV/SV display, so you can check the actual value and set value at a glance.
By attaching the SB (support rod and bracket set), flasks and external sensors can be fixed in the tank with clamps. Circulation method: Closed system
Temperature range (℃): -30 to +80
Cooling capacity (at20℃): 50Hz/370W, 60Hz/384W
Temperature setting and display method: Key input method (0.1℃), PV/SV digital two-level display
Temperature control method: Microcomputer PID control
Temperature sensor: Thermocouple (Pt100Ω)
Temperature control accuracy: ±0.1℃ (may exceed range depending on conditions)
Heater: 1kW
Size: 305×490×700mm
Inside dimensions: 239 x 299 x 200 mm
Effective opening dimensions: 235 x 162 x 200 mm
Liquid tank: Approx. 12L
Material: Water tank and cooling coil: Stainless steel (SUS304)
Types of liquid used: Pure water, clean water, ethylene glycol, ethyl alcohol
Refrigerant: R448A
Circulation pump: Maximum flow rate: 6.7/7.5L/min, Maximum head: 3.5/5.0m (50/60Hz)
Circulation nozzle outer diameter: φ11mm (suitable tube inner diameter φ8mm)
Safety devices: Self-diagnosis function (detection of upper and lower temperature limits, float type dry-burn prevention, sensor abnormality, heater disconnection, leakage current/overcurrent breaker, refrigerator overload relay)
External input/output: External temperature sensor input terminal (for Pt100), analog output system for thermometer (1 to 5 V), alarm output terminal (DC12 to 17 V, 20 mA)
Timer function: 1 minute to 48 hours (in 1 minute increments)
Power supply: AC100V 50/60Hz
Maximum operating current: 15A
Weight: 39kg
Accessories: 2 external circulation nozzles, 2 insulated hoses (inner diameter φ8 mm x 1 m)
*The freezer will not work if the liquid temperature is over 40°C.
*Please avoid continuous operation at high temperatures (around 80°C).
*Circulation pump performance is measured when the pump is used alone.
View full details