This is a two-in-one radiation thermometer that can also be used with K-type thermocouple sensors (sold separately, IK series).
The laser marker is a two-point type and can measure up to +1600°C.
A surface temperature measuring thermometer with a two-point laser marker function that provides an indication of the measurement position.
Measurements are possible from -60 to +1600°C.
Gun-type design that fits in your hand and is easy to use.
A hybrid type that can also measure temperature (-64 to +1400°C) using a K-type thermocouple thermometer (sold separately).
Temperature display: 0.1℃ unit
Surface temperature can be measured in about 1 second.
Equipped with a HOLD function that fixes and displays the measurement value.
Emissivity: Variable in increments of 0.01 in the range of 0.10 to 1.00
Comes with MAX (maximum value)/MIN (minimum value) memory function.
Comes with AVERAGE display.
Comes with HI (upper limit)/LO (lower limit) alarm function.
Comes with backlight function.
Equipped with auto power off function. (Power will automatically turn off if there is no operation for 1 minute after the last button operation. 12 minutes when measuring thermocouples.)
Comes with LOCK (continuous measurement) function.
PSC mark certified product Measurement range (℃): -60 to +1600
Resolution (℃): -19.9 to +199.9/0.1, Other/1
Accuracy: ±2%rdg or ±3℃, whichever is greater
Repeatability: ±0.6℃ or ±1.2%rdg, whichever is greater
Emissivity: 0.10 to 1.00 (0.01 steps)
Distance factor: D:S = 75:1
Response time: 1 second
Size (mm): 47 x 196 x 200
Weight(g): Approx. 392
Power supply: 2 AAA batteries (included for testing)
Functions: Maximum value display, minimum value display, average value display, hold, laser marker (2 points), backlight
K thermocouple measurement (sensor sold separately, IK series sensor probe), auto power off, thermocouple measurement, hard case included
*When using the contact type, a sensor (sold separately) is required. Please choose from the IK series.