Skip to product information
1 of 4

ガステック

Detector tube (Gastec) Amines 180L 1 box

Detector tube (Gastec) Amines 180L 1 box

JAN:4571112672790  
Regular price ¥2,640
Regular price Sale price ¥2,640
Sale Sold out
Shipping calculated at checkout.
The concentration of various gases in the air can be easily measured using a direct reading method. Measurements can be performed using just one detector (pump) by simply changing the detector tube. Since it is a direct reading type, it is accurate and there are no individual differences. Concentration measurement is completed in 30 to 240 seconds for one stroke (100 ml). Detector tube name: 180 L Amines Quantity: 1 box (10 pieces) Number of measurements per box: 10 Expiration date (months): 36 Measurement gas name: N,N-diethylethanolamine Measurement range: 0.6 to 12 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: N,N-dimethylethylamine Measurement range: 0.3 to 6 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: NN-dimethylethanolamine Measurement range: 0.65 to 13 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: N-methylmorpholine Measurement range: 0.3 to 6 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: n-butylamine Measurement range: 0.55 to 11 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Amines Measurement range: 0.5 to 10 ppm Standard number of suctions (n): 1 Measurement gas name: Isopropylamine Measurement range: 0.45 to 9 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Ethanolamine (monoethanolamine) Measurement range: 1.95 to 39 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Ethylamine Measurement range: 0.45 to 9 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Ethylenediamine Measurement range: 0.9 to 18 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Di-n-butylamine Measurement range: 0.4 to 8 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Diisopropylamine Measurement range: 0.3 to 6 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Diethylamine Measurement range: 0.45 to 9 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Dethylenetriamine Measurement range: 0.95 to 19 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Cyclohexylamine Measurement range: 0.5 to 10 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Dipropylamine Measurement range: 0.35 to 7 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Dimethylaminopropylamine Measurement range: 0.6 to 12 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Dimethylamine Measurement range: 0.45 to 9 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Tetramethylenediamine Measurement range: 0.8 to 16 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Triethylamine Measurement range: 0.3 to 6 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Trimethylamine Measurement range: 0.25 to 5 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Propylamine Measurement range: 0.5 to 10 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Propyleneimine Measurement range: 0.35 to 7 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Hexamethylenediamine Measurement range: 1.55 to 31 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Hexylamine Measurement range: 0.65 to 13 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Pentamethylenediamine Measurement range: 0.75 to 15 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Methylamine Measurement range: 0.5 to 10 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used Measurement gas name: Morpholine Measurement range: 0.5 to 10 ppm Standard number of suctions (n): 1 Special note: Conversion coefficient used *Please note that calibration may not be possible depending on the type of gas.
View full details

当日出荷 100万商品 !!

医療・産業機器から生活用品まで、幅広いジャンルの商品を取り揃え、カテゴリ数は2万3千件以上。今すぐ欲しい商品が見つかります!
お求めの商品はサイト内の検索機能、またはお気軽にチャットでご相談ください。迅速で丁寧なサポートをご提供いたします。