1
/
of
5
三和電気計器(株)
SANWA Digital Multimeter RD700 1 unit
SANWA Digital Multimeter RD700 1 unit
Regular price
¥13,517
Regular price
Sale price
¥13,517
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Catalog number: RD700 Features: ●Direct temperature measurement possible. (K-type sensor included) ●Large, easy-to-read LCD display. ●MAX recording function included. ●Supports high input impedance of 1000MΩ with little loss in voltage measurement. ●CE-compliant. ●Maximum display: 4000 counts ●Cancelable auto power-off function that activates after about 30 minutes ●Equipped with a buzzer to warn of incorrect insertion into current-only terminals ●Capacitor capacity measurement (cannot measure aluminum electrolytic capacitors with large leakage currents) ●50Hz to 1MHz frequency measurement Applications: ●For research and development. ●For electronic work. ●For building maintenance. ●For facility preservation maintenance. Specifications: ●DC voltage (V): 1000 ●AC voltage (V): 1000 ●DC current (A): 10 ●AC current (A): 10 ●Resistance (Ω): 40M ●Detection method: Average value rectification (MEAN) ●Continuity check: Buzzer sounds at 20 to 120Ω or less Open voltage: less than 0.4V●Calibration documents: Supported●Power supply (V): 1 x stacked 9V dry battery (6F22) (included)●Width (mm): 87●Depth (mm): 55●Height (mm): 179●Power supply: 1 x stacked 9V dry battery (6F22) (included)●Width (mm): 87●Depth (mm): 55●Height (mm): 179●Continuous use time (h): Approximately 150 hours●Maximum display (count): 4000●Capacitor (F): 3000μ●Temperature (℃): -20 to 300●Frequency (Hz): 1M●Diode test: Open voltage less than 1.6V●Detection method: Average value rectification (MEAN)●High input impedance 1000MΩ●Temperature measurement possible●Frequency measurement up to 1MHz possible●New model fuse specification 1: 0.63A/500V IR50kA Φ6.3×32mm ceramic tube (F1198) ● New model fuse specification 2: 12.5A/500V IR20kA Φ6.3×32mm ceramic tube (F1199) ● Old model fuse specification 1: 0.63A/250V IR1.5kA Φ5.2×20mm ceramic tube (F2019) ● Old model fuse specification 2: 12.5A/500V IR20kA Φ6.3×32mm ceramic tube (F1199) Set contents/accessories: ● Test lead (TL-23a) ● K-type thermocouple sensor (K-250PC) ● Holster (H-50) ● Instruction manual Caution: ● Do not use if the main unit or test lead is damaged. ● Do not hold the test pin side of the test probe beyond the flange during measurement. ● Connect the ground side (black test lead) of the test lead first, then connect the live side (red test lead). When disconnecting, first separate the live side. ●Do not switch to another function or range or insert the test lead plug into another measurement terminal during measurement. ●Use fuses of the specified shape and rating.
View full details
